There's an intoxilyzer breath alcohol instrument to meet your law enforcement or workplace testing needs. Intoxilyzer breath alcohol testers are accurate, rugged and provide immediate results. |

AUTOMATIC BREATH SAMPLING
There’s no counting, no need to push and hold buttons, and no need to take your eyes off the subject to obtain a breath reading with the Intoxilyzer® 300. It automatically draws a breath sample from the mouthpiece for analysis after the subject blows for 4-6 seconds.
VERSATILE USE
The Intoxilyzer® 300 has many uses, including law enforcement DUI testing, Department of Transportation mandated screening tests and other employee alcohol testing programs. The Intoxilyzer® 300 appears on the NHTSA Conforming Products List.
Automatic breath sampling system
-Visual and audible prompts lead the operator through the testing and calibration modes
-Fuel cell sensor reacts only to alcohol
-Easy recall of last test results
-Manual sampling override for subjects with “shy lung” condition
- Automated, simple calibration routine
-Portable for testing anywhere. No external electrical supply or battery chargers needed.
-Y2K compliant
SPECIFICATIONS:
Detector—Electrochemical fuel cell
Specificity —Fuel cell sensor is unaffected by acetone, paint and glue fumes, foods, confections, methane, and practically any other substance found in the human breath.
Instrument Control—By microcontroller
Sampling—Automatic after the subject blows for 4-6 seconds
Response Time—Within five seconds of sampling, depending on alcohol concentration
Reset Time—Immediate at zero alcohol reading, up to two minutes after a positive breath test
RF Interference —Instrument is immune to high levels of radio frequency interference
Display—Four-digit LCD
Audible Indicator—Beeper signals fault conditions and changes in instrument status.
Visual Indicator—Two LED lights indicate status (Wait or Flow/Analyzing)
Recommended Operating Temperature—23° to 104°F (-5° to 40°C)
Calibration —Dry gas or wet bath simulator
Dimensions—3¼” wide x 1¾” deep x 6¾” high (8.3 cm wide x 4.4 cm deep x 17.1 cm high)
Weight—One pound (.45 kg)
Power Supply—Five “AA” batteries (included)
Included With Each Instrument—Five mouthpieces, illustrated operator’s manual, carrying case
Optional Accessories—Rechargeable power unit
Warranty—One year, parts and labor
|
A TRULY FLEXIBLE INSTRUMENT The Intoxilyzer® 400PA is fully automatic! Highly accurate, simple operation. Results are displayed in seconds and can be automatically printed. The Intoxilyzer® 400PA appears on the NHTSA Conforming Products List. It has standard memory for 500 test results, and optional memory is available for up to 5,000 test results. With optional software packages, the 400PA can be connected to a PC for data download or for conducting tests with full data entry capability.
The Intoxilyzer® 400PA operates in up to three modes—Precursory, Analyze, or Precursory/Analyze. If the optional printer is attached, results are automatically printed in the Analyze mode. Precursory mode allows for mass screening of subjects without the need for disposable mouthpieces. A reusable plastic “cup” is used to collect the sample without contact by the subject. An approximate alcohol reading is given, allowing quick disposition of negative test subjects, and a quick decision whether to continue testing a positive subject. Analyze mode requires the use of a disposable mouthpiece, and gives an exact reading of the breath alcohol concentration. In the third mode, Precursory/Analyze, if the precursory test is above a preset limit, the instrument automatically enters the Analyze mode for a precise reading. The 400 PA is also available in “Pass, Warn, Fail” mode, and can be configured at the factory to the customers specific requirements—the 400PA lets you design your instrument to meet your needs.
FEATURES
- Fully automatic breath sampling system
- Data storage of more than 500 tests
- RS-232 communications port for printing and/or downloading of test results
- Automated calibration
- DOT/NHTSA approved
- Visual and audible prompts lead the operator through the testing and calibration modes
- Factory configurable to meet a wide range of needs
- Y2K compliant
SPECIFICATIONS:
Detector—Electrochemical fuel cell
Specificity—Fuel cell sensor is unaffected by acetone, paint and glue fumes, foods, confections, methane, and practically any other substance found in the human breath.
Instrument Control—By microcontroller
Sampling—Automatic after the subject blows for 4-6 seconds
Accuracy—±.005 BrAC up to 0.100 BrAC and ±5% above 0.100 BrAC, which meets DOT specifications
Response Time—Within five seconds of sampling, depending on alcohol concentration
Reset Time—Immediate at zero alcohol reading, up to two minutes after a positive breath test
RF Interference—The plastic used for the instrument’s housing contains embedded protection from radio frequency interference.
Display—Four-digit LCD Audible Indicator—Beeper signals fault conditions and changes in instrument status.
Visual Indicator—Four LED lights indicate status (Wait, Ready, Flow, Analyzing)
Calibration—Dry gas or wet bath simulator. Instrument can be configured to disable itself if calibration is overdue.
Communications Port—Two-channel, RS-232 serial interface to printer or PC
Memory Function—Stores more than 500 test results including date and time. Reprints last breath test even if instrument has been switched off and main power source is removed. Stored tests can be downloaded to the printer or a PC.
Optional Memory—Additional memory capacity up to 5,000 total tests is available
Recommended Operating Temperature—23° to 104°F (-5° to 40°C). The fuel cell is automatically heated at low temperatures.
Dimensions—3¼” wide x 1¾” deep x 6¾” high (sensor) (8.3 cm wide x 4.4 cm deep x 17.1 cm high)
Weight—One pound (.45 kg)
Power Supply—Five “AA” batteries (included)
Included With Each Instrument— Storage case, 5 mouthpieces, operator’s manual
Optional Accessories— Calibration key, printer, printer paper, rechargeable power unit, 12-volt power supply, waterproof case, Data-400 software for downloading of test results to a PC, OnLine-400 software for controlling the test process directly from a PC, calibration supplies, custom factory configuration of your instrument to a wide range of capabilities
Warranty—One year, parts and labor
|
VERSATILE USE The S-D2 is a versatile breath alcohol screener. Its lightweight and rugged design makes it the perfect instrument whenever a quantitative result is necessary. The S-D2 can be used in many situations, including:
- Preliminary law enforcement “Driving Under the Influence” screening
- Screening tests for Department of Transportation-mandated “safety sensitive” employee testing. The S-D2 appears on the NHTSA Conforming Products List
.- Employee alcohol testing as a part of a comprehensive company safety program.
FEATURES
- Fuel cell sensor reacts only to alcohol - Unique “A” and “B” lights show the operator when the subject is providing a sufficient sample for analysis
- Sampling system ensures a deep lung breath sample
- No warm-up time, always ready to use - Fast, easy testing sequence
- Quick instrument recovery time allows for testing to be done on several people within a short time
- Portable for testing anywhere. No external electrical supply or battery chargers are needed.
- Y2K compliant
SPECIFICATIONS:
Detector—Electrochemical fuel cell
Specificity—Fuel cell sensor is unaffected by acetone, paint and glue fumes, foods, confections, methane, and practically any other substance found in the human breath.
Visual Indicators—“A” and “B” LED lights indicate when a subject has blown hard enough and long enough to ensure a quality, deep lung breath sample
Display—Three-digit illuminated LCD
Sampling—A pressure vs. time system ensures the donor provides a deep lung air sample
Accuracy—±.005 BrAC up to 0.100 BrAC and ±5% above 0.100 BrAC, which meets DOT specifications
Response Time—Within 45 seconds of sampling, depending on alcohol concentration
Reset Time—Immediate at zero alcohol reading, up to two minutes after a positive breath test Recommended
Operating Temperature—32° to 100°F (0° to 40°C)
Calibration—Dry gas or wet bath simulator
Dimensions—2¾” wide x 1½” deep x 5” high (7 cm wide x 3.8 cm deep x 12.7 cm high)
Weight—7½ oz. (213 grams)
Power Supply—One 9-volt battery (included) provides about 500 tests. Display shows “L” when battery voltage is low.
Included With Each Instrument—25 mouthpieces, calibration screwdriver, leather pouch, wrist strap, temperature indicator, illustrated operator’s manual
Optional Accessories—Carrying case
Warranty—One year, parts and labor
|
UNIQUE INSTRUMENT The Intoxilyzer® 400 was specifically designed for employee testing programs. It’s fully automatic! Results are displayed in seconds and automatically printed. If a DOT screening test is positive, the Intoxilyzer® 400 can count down the 15-minute observation period before the confirmation test is performed.
The Intoxilyzer® 400 appears on the NHTSA Conforming Products List. The Intoxilyzer® 400 operates in three modes—Screening, Confirmatory or Screening/Confirmatory. Results are automatically printed in the Confirmatory and Screening/Confirmatory modes.
- Automatic breath sampling system
- Data storage of more than 100 tests
- RS-232 communications port for printing and/or downloading of test results
- Visual and audible prompts lead the operator through the testing and calibration modes
- Y2K compliant
SPECIFICATIONS:
Detector—Electrochemical fuel cell
Specificity—Fuel cell sensor is unaffected by acetone, paint and glue fumes, foods, confections, methane, and practically any other substance found in the human breath.
Instrument Control—By microcontroller
Sampling—Automatic after the subject blows for 4-6 seconds
Accuracy—±.005 BrAC up to 0.100 BrAC and ±5% above 0.100 BrAC, which meets DOT specifications
Response Time—Within five seconds of sampling, depending on alcohol concentration
Reset Time—Immediate at zero alcohol reading, up to two minutes after a positive breath test
RF Interference—Instrument is immune to high levels of radio frequency interference.
Display—Four-digit LCD
Audible Indicator—Beeper signals fault conditions and changes in instrument status.
Visual Indicator—Two LED lights indicate status (Wait, Ready, Flow, Analyzing)
Calibration—Dry gas or wet bath simulator
Communications Port—Two-channel, RS-232 serial interface to printer or PC for test data transfer
Memory Function—Stores more than 100 test results including date and time. Reprints last breath test even if instrument has been switched off and main power source is removed. Stored tests can be downloaded to the printer or a PC.
Recommended Operating Temperature—23° to 104°F (-5° to 40°C). The fuel cell is automatically heated at low temperatures.
Dimensions—3¼” wide x 1¾” deep x 6¾” high (sensor) (8.3 cm wide x 4.4 cm deep x 17.1 cm high)
Weight—One pound (.45 kg)
Power Supply—Five “AA” batteries (included)
Included With Each Instrument—Printer, carrying bag, three rolls of printer paper, printer connector cable, 100 mouthpieces, operator’s manual
Optional Accessories—400-DH software for downloading of test results to a PC, rechargeable power unit, 12-volt power supply
Warranty—One year, parts and labor
|
RUGGED PORTABILITY The Intoxilyzer® 200 is a breath tester and printer inside a rugged Pelican® case. Easily portable from site to site, the Intoxilyzer® 200 is built to withstand the extremes. It has a rechargeable battery capable of eight hours continuous use. The unit can also be used as a desktop instrument for stationary testing.
The Intoxilyzer® 200/200D can be used for both screening and confirmatory U.S. Department of Transportation-mandated employee alcohol testing. Results can be printed on three-part paper. The Intoxilyzer® 200/200D appears on the NHTSA Conforming Products List and is Y2K compliant. EASY TO USE The Intoxilyzer® 200/200D is microprocessor controlled which makes it very easy to operate.
The operator is prompted through the testing, calibration check and recalibration processes by an illuminated display. EASY TO USE The Intoxilyzer® 200/200D is microprocessor controlled which makes it very easy to operate. The operator is prompted through the testing, calibration check and recalibration processes by an illuminated display.
In addition to performing standard breath alcohol tests, the Intoxilyzer® 200/200D has two additional test modes:
1) A Custom mode that performs a calibration check if a test result is .02 or above, and 2) A Fitness for Duty mode that automatically counts a user-configured waiting period (up to 20 minutes) between two tests.
DATA STORAGE
The 200D version includes a keyboard for data entry of the subject’s complete name, company and ID number as well as the operator’s name and ID number. Using CMI’s own 200-Soft, up to 150 stored test results can be downloaded to a PC into popular user-selected software programs.
SPECIFICATIONS:
Detector—Electrochemical fuel cell
Specificity—Fuel cell sensor is unaffected by acetone, paint and glue fumes, foods, confections, methane, and practically any other substance found in the human breath.
Instrument Control—By microcontroller
Sampling—A pressure vs. time system ensures the donor provides a deep lung air sample
Accuracy—±.005 BrAC up to 0.100 BrAC and ±5% above 0.100 BrAC, which meets DOT specifications
Response Time—Within 45 seconds of sampling, depending on alcohol concentration
Reset Time—Immediate at zero alcohol reading, up to two minutes after a positive breath test
Display—Four-digit LCD
Audible Indicator—Beeper signals fault conditions and changes in instrument status.
Visual Indicator—Instrument indicates operating conditions and instructs operator through procedures.
Calibration—Dry gas or wet bath simulator
Communications Port—Two-channel, RS-232 serial interface to printer or PC for test data transfer
Memory Function—Stores more than 150 tests.
Printer—A reliable Epson™ impact printer utilizes a long-life ribbon and standard 2¼” wide paper roll provides three copies.
Recommended Operating Temperature—55° to 95°F (10° to 35°C).
Dimensions—18½” wide x 15½” deep x 7” high (47 cm wide x 39.4 cm deep x 17.8 cm high)
Weight—18 pounds (8.17 kg)
Power Supply—Rechargeable 12 volt battery, standard AC line or 12 volt automobile cigarette lighter (optional)
Included With Each Instrument—100 mouthpieces, 110 volt transformer, three rolls of printer paper, printer ribbon, instructional video and operator’s manual. 200D model includes keyboard 200-Soft and PC link.
Optional Accessories—Dust cover
Warranty—One year, parts and labor
|
THE SMALLEST HANDHELD SCREENER AVAILABLE At only 4¾” high x 2½” wide x 1¼” deep, the Intoxilyzer® S-D5 will get the job done without taking up lots of room. It’s small but packed with features and ready to use in many testing situations: Preliminary law enforcement “Driving Under the Influence” screening Employee alcohol testing as a part of a comprehensive company safety program.
SPECIFICATIONS:
Detector—Electrochemical fuel cell
Specificity—Fuel cell sensor is unaffected by acetone, paint and glue fumes, foods, confections, methane, and practically any other substance found in the human breath.
Sampling—Automatic after subject blows for 4-6 seconds. An override feature for manual sampling is provided.
Display—Large, three-digit LED (9/16” x 5/16”)
Memory—Result of the last test is stored and can be recalled until the next test is taken.
Accuracy—Meets DOT specifications of ±.005 BrAC up to 0.100 BrAC and ±5% above 0.100 BrAC.
Response Time—Within five seconds of sampling, depending on alcohol concentration
Reset Time— Immediate at zero alcohol reading, up to two minutes after a positive test
Audible Indicator—Beeper signals fault conditions and changes in instrument status.
Visual Indicator—LEDs are used for alpha prompting of the operator.
Instrument Control—By micro controller
Recommended Operating Temperature—23° to 104°F (-5° to 40°C)
Calibration—Automated procedure by either dry gas or wet bath simulator
Dimensions—2½” wide x 4¾” high x 1¼” deep
Power Supply—Two “AAA” batteries
Optional Accessories— Storage case, protective leather pouch
Warranty—One year, parts and labor |
|